● Industries
Infrastructure & data centres
Transformers for rail, airports and data halls.

Low-loss dry-type and amorphous transformers, prefabricated substations and switchgear for data centres, metro systems, airports, ports and tunnels — where uptime and fire safety come first.
- Amorphous low-loss cores
- Redundant N+1 layouts
- IP23 enclosures & monitoring
Featured transformers & substations
SCB11-35
Dry-type transformers35 kV Low-Noise Dry-Type Power TransformerDown to 45 dB — quiet enough for hotels, hospitals and city centres.
- Rated capacity
- 50–20,000 kVA
- Rated voltage
- 20–35 kV
- Standards
- ≤45 dB
SCB10
Dry-type transformersSCB10 / SCB11 / SCB13 Cast-Resin Dry-Type TransformerFire-safe, oil-free power for buildings, hospitals and factories.
- Rated capacity
- 30–2,500 kVA
- Rated voltage
- 6–11 / 0.4 kV
- Standards
- IEC 60076-11
YB-12/0.4
Box-type substationsYB European-Style Prefabricated SubstationHV switchgear, transformer and LV board in one weatherproof enclosure.
- Rated capacity
- 100–1,600 kVA
- Rated voltage
- 12 / 0.4 kV
- Standards
- IEC 62271-202
SBH15-M
Oil-immersed transformersSBH15 Amorphous-Alloy Oil-Immersed TransformerAbout 70% less no-load loss — energy savings every hour it is energised.
- Rated capacity
- 30–2,500 kVA
- Rated voltage
- 6–11 / 0.4 kV
- Standards
- −70% P0
KYN28A-12
HV & LV switchgearKYN28A-12 Metal-Clad Withdrawable Switchgear12 kV switchgear with vacuum breakers and full interlocking.
- Rated capacity
- 630–4,000 A
- Rated voltage
- 12 kV
- Standards
- IEC 62271-200
GGD
HV & LV switchgearGGD / GCS / MNS Low-Voltage SwitchgearMain distribution boards, MCCs and capacitor banks to IEC 61439.
- Rated capacity
- 400–4,000 A
- Rated voltage
- 0.4 kV
- Standards
- IEC 61439

Power cables
The transformer is only as good as the cable feeding it.
Xinya started as a power cable manufacturer. Every transformer and substation we supply can ship with the MV and LV cables specified for it — sized, terminated and tested.
- MV power cable
XLPE-insulated copper cable 6/10 to 26/35 kV to IEC 60502-2, armoured or unarmoured, from our own lines.
- Terminations & joints
Heat-shrink or cold-shrink terminations matched to bushings, elbow connectors and switchgear.
- One set of test records
Cable routine tests delivered together with the transformer test report for your inspector.
- One shipment
Transformers, substations and cable drums consolidated in one container booking.
● RFQ
Planning a transformer or substation project?
Tell us the load, voltage levels and site. You get a selection, outline drawing and quotation within one working day.