About Xinya Power

A power cable manufacturer that delivers complete transformer and substation packages.

01

From cables to complete substations

Xinya Power Cables began by manufacturing power cables. Our customers kept asking for the transformer at the other end of the cable — so we added transformers and substations, and now ship both as one package.

02

Qualified manufacturing

A core team with 30 years of transformer experience, management certified to ISO 9001 / 14001 / 45001, and type tests by a CNAS-accredited national laboratory.

03

Engineering support

Our engineers select the rating, check losses and impedance, specify the cabling and prepare documents for your utility — in 13 languages.

40 MVAlargest rating · from 10 kVA
220 kVhighest voltage class
−70%no-load loss with amorphous cores
13languages of engineering support

What we commit to

  • Honest data sheets with guaranteed losses
  • Matched cabling for every transformer
  • Fast, documented quotations
  • After-sales support across time zones

Manufacturing

Built on real production lines — not a trading desk.

Our transformers are built on real production lines: foil and wire winding, vacuum resin casting, oil-filling lines and a full routine-test bay.

Cast-resin transformer assembly line
01Cast-resin transformer assembly line
Coil winding and core stacking
02Coil winding and core stacking
Routine test control desk
03Routine test control desk
Oil-immersed final assembly
04Oil-immersed final assembly
Vacuum-cast resin coils
05Vacuum-cast resin coils
Lead and tap connection
06Lead and tap connection

Quality & certification

Every unit tested before it ships.

Routine tests on 100% of units, type tests by a CNAS-accredited national laboratory, and a management system certified to ISO 9001, ISO 14001 and ISO 45001.

Routine tests on every transformer
01Winding resistance & voltage ratio✓ 100%
02Vector group & polarity✓ 100%
03No-load loss & current✓ 100%
04Load loss & impedance✓ 100%
05Applied & induced voltage withstand✓ 100%
06Partial discharge (dry type)✓ 100%
07Oil dielectric strength & tightness (oil type)✓ 100%
  • IEC 60076-1/-2/-3/-5/-11
  • IEC 62271-200/-202
  • GB 1094
  • GB/T 10228
  • GB/T 6451
  • GB/T 17467
  • IEC 60502-2
ISO 9001 · 14001 · 45001ISO 9001 · 14001 · 45001ISO 9001 · 14001 · 45001

ISO 9001 · 14001 · 45001

Type-test reportType-test reportType-test report

Type-test report

From inquiry to energisation

A clear path, with an engineer — not a salesperson — at every step.

  1. STEP 01Inquiry

    Send load, voltages, site and standard. Reply within one working day.

  2. STEP 02Engineering

    Rating, impedance, losses and outline drawing for your approval.

  3. STEP 03Production

    Core, winding, casting or oil filling with progress photos.

  4. STEP 04Testing

    Routine tests, optional witness test or video FAT.

  5. STEP 05Delivery

    Seaworthy packing, documents and installation guidance.

● RFQ

Planning a transformer or substation project?

Tell us the load, voltage levels and site. You get a selection, outline drawing and quotation within one working day.