● Mga industriya
Solar, wind at storage
Step-up transformer para sa renewable.

Box-type step-up transformer at grid-connection power transformer para sa PV, wind at battery plant, dinisenyo para sa inverter harmonics at araw-araw na load cycle.
- 0.8 / 35 kV step-up unit
- Double-split LV winding
- Grid connection hanggang 220 kV
Mga industriya
Mula grid hanggang sa huling load — iisang supplier.
Pumili ng senaryo at sundan ang kuryente sa bawat voltage level, kasama ang tamang kagamitan sa bawat node.
Bawat PV o wind block ay nagtataas ng inverter voltage sa 10–35 kV sa box transformer; ikinokonekta ng collector switchgear at main transformer ang planta sa grid.
MV / LV cable: XLPE Medium-Voltage Power Cable YJV / YJV22Mga tampok na transformer at substation
XY-ZGS-PV
Compact transformerSolar PV Step-Up Box TransformerMula inverter papuntang grid para sa PV, wind at battery plant.
- Rated na kapasidad
- 500–3,150 kVA
- Rated na boltahe
- 0.8 / 35 kV
- Mga pamantayan
- IEC 60076
XY-SZ11-35
Power transformer35 kV / 66 kV Power Transformer na may OLTCSubstation at industrial power transformer mula 3.15 hanggang 20 MVA.
- Rated na kapasidad
- 3.15–20 MVA
- Rated na boltahe
- 33–66 kV
- Mga pamantayan
- IEC 60076
ZGS11-H
Compact transformerZGS11 American Pad-Mounted Compact TransformerTransformer, load switch at fuse sa iisang sealed tank — apat na bolt lang i-install.
- Rated na kapasidad
- 30–1,600 kVA
- Rated na boltahe
- 10 / 0.4 kV
- Mga pamantayan
- IP33
KYN28A-12
HV at LV switchgearKYN28A-12 Metal-Clad Withdrawable Switchgear12 kV switchgear na may vacuum breaker at kumpletong interlock.
- Rated na kapasidad
- 630–4,000 A
- Rated na boltahe
- 12 kV
- Mga pamantayan
- IEC 62271-200
YJV / YJV22 8.7/15 kVGawa ng Xinya
Power cableXLPE Medium-Voltage Power Cable YJV / YJV22Ang cable sa pagitan ng switchgear at transformer — gawa ng Xinya.
- Rated na kapasidad
- 3×25–3×400 mm²
- Rated na boltahe
- 8.7/15–26/35 kV
- Mga pamantayan
- IEC 60502-2

Power cable
Ang transformer ay kasinghusay lang ng cable na nagpapakain dito.
Nagsimula ang Xinya bilang manufacturer ng power cable. Bawat transformer at substation ay puwedeng ipadala kasama ang MV at LV cable na tinukoy para dito — sukat, terminated at tested.
- MV power cable
XLPE-insulated copper cable 6/10 hanggang 26/35 kV ayon sa IEC 60502-2, armoured o hindi, mula sa sarili naming linya.
- Termination at joint
Heat-shrink o cold-shrink termination na tugma sa bushing, elbow connector at switchgear.
- Iisang set ng test record
Routine test ng cable na kasama ng test report ng transformer.
- Iisang shipment
Transformer, substation at cable drum sa iisang container booking.
● RFQ
May pinaplanong transformer o substation project?
Sabihin ang load, voltage level at site. Makakatanggap ka ng selection, drawing at quotation sa loob ng isang araw ng trabaho.