Transformer at substation equipment
Oil-immersed at dry-type transformer, power transformer, prefabricated at compact substation, switchgear, special transformer at MV cable.

S11-M
Oil-immersed transformerS13 Oil-Immersed Distribution Transformer 10 kVSealed, low-loss, walang maintenance — ang workhorse ng bawat distribution network.
- Rated na kapasidad
- 30–2,500 kVA
- Rated na boltahe
- 6–11 / 0.4 kV
- Mga pamantayan
- IEC 60076
SBH15-M
Oil-immersed transformerSBH15 Amorphous-Alloy Oil-Immersed TransformerMga 70% mas mababang no-load loss — tipid sa bawat oras na naka-energize.
- Rated na kapasidad
- 30–2,500 kVA
- Rated na boltahe
- 6–11 / 0.4 kV
- Mga pamantayan
- −70% P0
XY-S13-33
Oil-immersed transformer33 kV Oil-Immersed Distribution TransformerGawa para sa 11 kV at 33 kV na network sa Africa, Middle East at Asia.
- Rated na kapasidad
- 25–2,500 kVA
- Rated na boltahe
- 11 / 33 kV
- Mga pamantayan
- IEC 60076
SCB10
Dry-type transformerSCB10 / SCB11 / SCB13 Cast-Resin Dry-Type TransformerFire-safe at walang langis para sa gusali, ospital at pabrika.
- Rated na kapasidad
- 30–2,500 kVA
- Rated na boltahe
- 6–11 / 0.4 kV
- Mga pamantayan
- IEC 60076-11
SCB11-35
Dry-type transformer35 kV Low-Noise Dry-Type Power TransformerHanggang 45 dB — tahimik para sa hotel, ospital at sentro ng lungsod.
- Rated na kapasidad
- 50–20,000 kVA
- Rated na boltahe
- 20–35 kV
- Mga pamantayan
- ≤45 dB
SCBH15
Dry-type transformerSCBH15 Amorphous-Alloy Dry-Type TransformerAng efficiency ng amorphous core at ang kaligtasan ng cast resin.
- Rated na kapasidad
- 30–2,500 kVA
- Rated na boltahe
- 10 / 0.4 kV
- Mga pamantayan
- −70% P0
SGB10
Dry-type transformerSGB H-Class Open-Ventilated Dry-Type TransformerNOMEX® insulation para sa mahalumigmig, mainit at mabigat na load.
- Rated na kapasidad
- 30–2,500 kVA
- Rated na boltahe
- 10 / 0.4 kV
- Mga pamantayan
- Class H
XY-SZ11-35
Power transformer35 kV / 66 kV Power Transformer na may OLTCSubstation at industrial power transformer mula 3.15 hanggang 20 MVA.
- Rated na kapasidad
- 3.15–20 MVA
- Rated na boltahe
- 33–66 kV
- Mga pamantayan
- IEC 60076
XY-SZ11-110
Power transformer110 / 132 / 220 kV Power TransformerHigh-voltage grid transformer hanggang 40 MVA, dinisenyo bawat proyekto.
- Rated na kapasidad
- 16–40 MVA
- Rated na boltahe
- 110–220 kV
- Mga pamantayan
- IEC 60076
XY-D11
Distribution transformerSingle-Phase Pole-Mounted Transformer 10–160 kVACompact na single-phase power para sa rural electrification at riles.
- Rated na kapasidad
- 10–160 kVA
- Rated na boltahe
- 6.3–33 kV
- Mga pamantayan
- IEC 60076
YB-12/0.4
Box-type substationYB European-Style Prefabricated SubstationHV switchgear, transformer at LV board sa iisang weatherproof na enclosure.
- Rated na kapasidad
- 100–1,600 kVA
- Rated na boltahe
- 12 / 0.4 kV
- Mga pamantayan
- IEC 62271-202
ZGS11-H
Compact transformerZGS11 American Pad-Mounted Compact TransformerTransformer, load switch at fuse sa iisang sealed tank — apat na bolt lang i-install.
- Rated na kapasidad
- 30–1,600 kVA
- Rated na boltahe
- 10 / 0.4 kV
- Mga pamantayan
- IP33
XY-ZGS-PV
Compact transformerSolar PV Step-Up Box TransformerMula inverter papuntang grid para sa PV, wind at battery plant.
- Rated na kapasidad
- 500–3,150 kVA
- Rated na boltahe
- 0.8 / 35 kV
- Mga pamantayan
- IEC 60076
KYN28A-12
HV at LV switchgearKYN28A-12 Metal-Clad Withdrawable Switchgear12 kV switchgear na may vacuum breaker at kumpletong interlock.
- Rated na kapasidad
- 630–4,000 A
- Rated na boltahe
- 12 kV
- Mga pamantayan
- IEC 62271-200
GGD
HV at LV switchgearGGD / GCS / MNS Low-Voltage SwitchgearMain distribution board, MCC at capacitor bank ayon sa IEC 61439.
- Rated na kapasidad
- 400–4,000 A
- Rated na boltahe
- 0.4 kV
- Mga pamantayan
- IEC 61439
DKSC
Special transformerDKSC Grounding (Earthing) TransformerArtificial na neutral para sa ungrounded at delta na sistema.
- Rated na kapasidad
- 100–2,000 kVA
- Rated na boltahe
- 6–35 kV
- Mga pamantayan
- IEC 60076
YJV / YJV22 8.7/15 kVGawa ng Xinya
Power cableXLPE Medium-Voltage Power Cable YJV / YJV22Ang cable sa pagitan ng switchgear at transformer — gawa ng Xinya.
- Rated na kapasidad
- 3×25–3×400 mm²
- Rated na boltahe
- 8.7/15–26/35 kV
- Mga pamantayan
- IEC 60502-2
● RFQ
May pinaplanong transformer o substation project?
Sabihin ang load, voltage level at site. Makakatanggap ka ng selection, drawing at quotation sa loob ng isang araw ng trabaho.
