● Mga industriya
Industriya at mining
Maaasahang supply para sa planta at minahan.

Cast-resin at oil-immersed transformer, unit substation at switchgear na sinukat para sa motor starting, harmonics at tuloy-tuloy na operasyon.
- Dry type class F/H
- Unit substation hanggang 2,500 kVA
- MV at LV switchgear
Mga industriya
Mula grid hanggang sa huling load — iisang supplier.
Pumili ng senaryo at sundan ang kuryente sa bawat voltage level, kasama ang tamang kagamitan sa bawat node.
Tinatanggap ng prefabricated unit substation ang 10–35 kV na supply; ang cast-resin dry-type transformer at LV switchboard ang ligtas na nagpapagana sa motor, production line at building services sa loob.
MV / LV cable: XLPE Medium-Voltage Power Cable YJV / YJV22Mga tampok na transformer at substation
SCB10
Dry-type transformerSCB10 / SCB11 / SCB13 Cast-Resin Dry-Type TransformerFire-safe at walang langis para sa gusali, ospital at pabrika.
- Rated na kapasidad
- 30–2,500 kVA
- Rated na boltahe
- 6–11 / 0.4 kV
- Mga pamantayan
- IEC 60076-11
SGB10
Dry-type transformerSGB H-Class Open-Ventilated Dry-Type TransformerNOMEX® insulation para sa mahalumigmig, mainit at mabigat na load.
- Rated na kapasidad
- 30–2,500 kVA
- Rated na boltahe
- 10 / 0.4 kV
- Mga pamantayan
- Class H
SCB11-35
Dry-type transformer35 kV Low-Noise Dry-Type Power TransformerHanggang 45 dB — tahimik para sa hotel, ospital at sentro ng lungsod.
- Rated na kapasidad
- 50–20,000 kVA
- Rated na boltahe
- 20–35 kV
- Mga pamantayan
- ≤45 dB
S11-M
Oil-immersed transformerS13 Oil-Immersed Distribution Transformer 10 kVSealed, low-loss, walang maintenance — ang workhorse ng bawat distribution network.
- Rated na kapasidad
- 30–2,500 kVA
- Rated na boltahe
- 6–11 / 0.4 kV
- Mga pamantayan
- IEC 60076
YB-12/0.4
Box-type substationYB European-Style Prefabricated SubstationHV switchgear, transformer at LV board sa iisang weatherproof na enclosure.
- Rated na kapasidad
- 100–1,600 kVA
- Rated na boltahe
- 12 / 0.4 kV
- Mga pamantayan
- IEC 62271-202
KYN28A-12
HV at LV switchgearKYN28A-12 Metal-Clad Withdrawable Switchgear12 kV switchgear na may vacuum breaker at kumpletong interlock.
- Rated na kapasidad
- 630–4,000 A
- Rated na boltahe
- 12 kV
- Mga pamantayan
- IEC 62271-200
GGD
HV at LV switchgearGGD / GCS / MNS Low-Voltage SwitchgearMain distribution board, MCC at capacitor bank ayon sa IEC 61439.
- Rated na kapasidad
- 400–4,000 A
- Rated na boltahe
- 0.4 kV
- Mga pamantayan
- IEC 61439
YJV / YJV22 8.7/15 kVGawa ng Xinya
Power cableXLPE Medium-Voltage Power Cable YJV / YJV22Ang cable sa pagitan ng switchgear at transformer — gawa ng Xinya.
- Rated na kapasidad
- 3×25–3×400 mm²
- Rated na boltahe
- 8.7/15–26/35 kV
- Mga pamantayan
- IEC 60502-2

Power cable
Ang transformer ay kasinghusay lang ng cable na nagpapakain dito.
Nagsimula ang Xinya bilang manufacturer ng power cable. Bawat transformer at substation ay puwedeng ipadala kasama ang MV at LV cable na tinukoy para dito — sukat, terminated at tested.
- MV power cable
XLPE-insulated copper cable 6/10 hanggang 26/35 kV ayon sa IEC 60502-2, armoured o hindi, mula sa sarili naming linya.
- Termination at joint
Heat-shrink o cold-shrink termination na tugma sa bushing, elbow connector at switchgear.
- Iisang set ng test record
Routine test ng cable na kasama ng test report ng transformer.
- Iisang shipment
Transformer, substation at cable drum sa iisang container booking.
● RFQ
May pinaplanong transformer o substation project?
Sabihin ang load, voltage level at site. Makakatanggap ka ng selection, drawing at quotation sa loob ng isang araw ng trabaho.