● Mga industriya

Utility at power grid

Power at distribution transformer para sa network.

Mula 220 kV substation transformer hanggang 10 kVA pole-mounted unit, nagsusuplay kami sa utility at EPC ayon sa IEC 60076 at kanilang specification — may guaranteed losses at dokumentadong type test.

  • Hanggang 40 MVA / 220 kV
  • OLTC o off-circuit tap changer
  • Unit para sa rural electrification

Mga industriya

Mula grid hanggang sa huling load — iisang supplier.

Pumili ng senaryo at sundan ang kuryente sa bawat voltage level, kasama ang tamang kagamitan sa bawat node.

Dinadala ng step-up at primary substation transformer ang kuryente sa 10–35 kV feeder, kung saan ang sealed S13 o amorphous distribution transformer ang nagsusuplay sa mga bayan, barangay at negosyo.

MV / LV cable: XLPE Medium-Voltage Power Cable YJV / YJV22

Mga tampok na transformer at substation

110 / 132 / 220 kV Power TransformerXY-SZ11-110 Power transformer110 / 132 / 220 kV Power TransformerHigh-voltage grid transformer hanggang 40 MVA, dinisenyo bawat proyekto.
Rated na kapasidad
16–40 MVA
Rated na boltahe
110–220 kV
Mga pamantayan
IEC 60076
Tingnan ang produkto
35 kV / 66 kV Power Transformer na may OLTCXY-SZ11-35 Power transformer35 kV / 66 kV Power Transformer na may OLTCSubstation at industrial power transformer mula 3.15 hanggang 20 MVA.
Rated na kapasidad
3.15–20 MVA
Rated na boltahe
33–66 kV
Mga pamantayan
IEC 60076
Tingnan ang produkto
33 kV Oil-Immersed Distribution TransformerXY-S13-33 Oil-immersed transformer33 kV Oil-Immersed Distribution TransformerGawa para sa 11 kV at 33 kV na network sa Africa, Middle East at Asia.
Rated na kapasidad
25–2,500 kVA
Rated na boltahe
11 / 33 kV
Mga pamantayan
IEC 60076
Tingnan ang produkto
S13 Oil-Immersed Distribution Transformer 10 kVS11-M Oil-immersed transformerS13 Oil-Immersed Distribution Transformer 10 kVSealed, low-loss, walang maintenance — ang workhorse ng bawat distribution network.
Rated na kapasidad
30–2,500 kVA
Rated na boltahe
6–11 / 0.4 kV
Mga pamantayan
IEC 60076
Tingnan ang produkto
Single-Phase Pole-Mounted Transformer 10–160 kVAXY-D11 Distribution transformerSingle-Phase Pole-Mounted Transformer 10–160 kVACompact na single-phase power para sa rural electrification at riles.
Rated na kapasidad
10–160 kVA
Rated na boltahe
6.3–33 kV
Mga pamantayan
IEC 60076
Tingnan ang produkto
DKSC Grounding (Earthing) TransformerDKSC Special transformerDKSC Grounding (Earthing) TransformerArtificial na neutral para sa ungrounded at delta na sistema.
Rated na kapasidad
100–2,000 kVA
Rated na boltahe
6–35 kV
Mga pamantayan
IEC 60076
Tingnan ang produkto
KYN28A-12 Metal-Clad Withdrawable SwitchgearKYN28A-12 HV at LV switchgearKYN28A-12 Metal-Clad Withdrawable Switchgear12 kV switchgear na may vacuum breaker at kumpletong interlock.
Rated na kapasidad
630–4,000 A
Rated na boltahe
12 kV
Mga pamantayan
IEC 62271-200
Tingnan ang produkto
XLPE Medium-Voltage Power Cable YJV / YJV22YJV / YJV22 8.7/15 kVGawa ng Xinya Power cableXLPE Medium-Voltage Power Cable YJV / YJV22Ang cable sa pagitan ng switchgear at transformer — gawa ng Xinya.
Rated na kapasidad
3×25–3×400 mm²
Rated na boltahe
8.7/15–26/35 kV
Mga pamantayan
IEC 60502-2
Tingnan ang produkto
ConductorXLPE Cu screenArmourPVC / PE Power cable

Power cable

Ang transformer ay kasinghusay lang ng cable na nagpapakain dito.

Nagsimula ang Xinya bilang manufacturer ng power cable. Bawat transformer at substation ay puwedeng ipadala kasama ang MV at LV cable na tinukoy para dito — sukat, terminated at tested.

  • MV power cable

    XLPE-insulated copper cable 6/10 hanggang 26/35 kV ayon sa IEC 60502-2, armoured o hindi, mula sa sarili naming linya.

  • Termination at joint

    Heat-shrink o cold-shrink termination na tugma sa bushing, elbow connector at switchgear.

  • Iisang set ng test record

    Routine test ng cable na kasama ng test report ng transformer.

  • Iisang shipment

    Transformer, substation at cable drum sa iisang container booking.

● RFQ

May pinaplanong transformer o substation project?

Sabihin ang load, voltage level at site. Makakatanggap ka ng selection, drawing at quotation sa loob ng isang araw ng trabaho.