● Transformer · substation · cable

Kuryente, maaasahang na-transform. Dumarating na handang i-energize.

Oil-immersed at dry-type transformer, power transformer hanggang 220 kV, prefabricated substation at ang MV cable na nagdurugtong sa kanila — dinisenyo ayon sa IEC 60076, type-tested at ipinapadala sa buong mundo.

Ratings
10 kVA – 40 MVA
Voltage class
hanggang 220 kV
Cooling
ONAN · ONAF · AN · AF
Pamantayan
IEC 60076 · IEC 62271
FIG. A · Saklaw ng produkto
33 kV Oil-Immersed Distribution Transformer HV na boltahe11 / 33 / 35 kV Tank / enclosureConservator with radiators Cooling methodONAN / ONAF Rated na kapasidad25 – 2,500 kVA
35 kV Low-Noise Dry-Type Power Transformer HV na boltahe20 / 35 kV Insulation classF (155 °C) Sound level≤ 45 dB(A) Cooling methodAN / AF
YB European-Style Prefabricated Substation Ingress protectionIP34D Transformer100 – 1,600 kVA HV compartment12 kV LV compartment0.4 kV · 8–15
40 MVApinakamalaking rating · mula 10 kVA
220 kVpinakamataas na voltage class
−70%no-load loss gamit ang amorphous core
13wika ng engineering support

02 — Mga modelo

Mga tampok na transformer at substation

May data sheet, losses at type test sa bawat product page.

S13 Oil-Immersed Distribution Transformer 10 kVS11-M Oil-immersed transformerS13 Oil-Immersed Distribution Transformer 10 kVSealed, low-loss, walang maintenance — ang workhorse ng bawat distribution network.
Rated na kapasidad
30–2,500 kVA
Rated na boltahe
6–11 / 0.4 kV
Mga pamantayan
IEC 60076
Tingnan ang produkto
SBH15 Amorphous-Alloy Oil-Immersed TransformerSBH15-M Oil-immersed transformerSBH15 Amorphous-Alloy Oil-Immersed TransformerMga 70% mas mababang no-load loss — tipid sa bawat oras na naka-energize.
Rated na kapasidad
30–2,500 kVA
Rated na boltahe
6–11 / 0.4 kV
Mga pamantayan
−70% P0
Tingnan ang produkto
33 kV Oil-Immersed Distribution TransformerXY-S13-33 Oil-immersed transformer33 kV Oil-Immersed Distribution TransformerGawa para sa 11 kV at 33 kV na network sa Africa, Middle East at Asia.
Rated na kapasidad
25–2,500 kVA
Rated na boltahe
11 / 33 kV
Mga pamantayan
IEC 60076
Tingnan ang produkto
SCB10 / SCB11 / SCB13 Cast-Resin Dry-Type TransformerSCB10 Dry-type transformerSCB10 / SCB11 / SCB13 Cast-Resin Dry-Type TransformerFire-safe at walang langis para sa gusali, ospital at pabrika.
Rated na kapasidad
30–2,500 kVA
Rated na boltahe
6–11 / 0.4 kV
Mga pamantayan
IEC 60076-11
Tingnan ang produkto
35 kV / 66 kV Power Transformer na may OLTCXY-SZ11-35 Power transformer35 kV / 66 kV Power Transformer na may OLTCSubstation at industrial power transformer mula 3.15 hanggang 20 MVA.
Rated na kapasidad
3.15–20 MVA
Rated na boltahe
33–66 kV
Mga pamantayan
IEC 60076
Tingnan ang produkto
110 / 132 / 220 kV Power TransformerXY-SZ11-110 Power transformer110 / 132 / 220 kV Power TransformerHigh-voltage grid transformer hanggang 40 MVA, dinisenyo bawat proyekto.
Rated na kapasidad
16–40 MVA
Rated na boltahe
110–220 kV
Mga pamantayan
IEC 60076
Tingnan ang produkto
YB European-Style Prefabricated SubstationYB-12/0.4 Box-type substationYB European-Style Prefabricated SubstationHV switchgear, transformer at LV board sa iisang weatherproof na enclosure.
Rated na kapasidad
100–1,600 kVA
Rated na boltahe
12 / 0.4 kV
Mga pamantayan
IEC 62271-202
Tingnan ang produkto
ZGS11 American Pad-Mounted Compact TransformerZGS11-H Compact transformerZGS11 American Pad-Mounted Compact TransformerTransformer, load switch at fuse sa iisang sealed tank — apat na bolt lang i-install.
Rated na kapasidad
30–1,600 kVA
Rated na boltahe
10 / 0.4 kV
Mga pamantayan
IP33
Tingnan ang produkto

03 — Mga industriya

Mula grid hanggang sa huling load — iisang supplier.

Pumili ng senaryo at sundan ang kuryente sa bawat voltage level, kasama ang tamang kagamitan sa bawat node.

Dinadala ng step-up at primary substation transformer ang kuryente sa 10–35 kV feeder, kung saan ang sealed S13 o amorphous distribution transformer ang nagsusuplay sa mga bayan, barangay at negosyo.

MV / LV cable: XLPE Medium-Voltage Power Cable YJV / YJV22

04 — Sizing tool

Anong rating ang kailangan mo? Alamin sa loob ng 20 segundo.

Ilagay ang maximum demand ng site. Kinakalkula namin ang apparent power, pinipili ang susunod na standard rating at nagmumungkahi ng kagamitan — saka kinukumpirma ng engineer.

Instalasyon

Inirerekomendang rating

1,250kVA

Loading ng transformer: —

Full-load current

Mungkahing kagamitan

    Ipadala ang sizing para sa quote

    Tantiya: kVA = kW ÷ PF × (1 + paglago), loading ≤ 90%. Ang huling rating, impedance at losses ay kinukumpirma ng aming mga engineer.

    05 — Paggawa

    Gawa sa totoong production line.

    Ginagawa ang aming transformer sa totoong production line: foil at wire winding, vacuum resin casting, oil-filling line at kumpletong routine-test bay.

    Assembly line ng cast-resin transformer
    01Assembly line ng cast-resin transformer
    Coil winding at core stacking
    02Coil winding at core stacking
    Routine test control desk
    03Routine test control desk
    Final assembly ng oil-immersed
    04Final assembly ng oil-immersed
    Vacuum-cast resin coil
    05Vacuum-cast resin coil
    Lead at tap connection
    06Lead at tap connection

    06 — Kalidad at sertipikasyon

    Tinetest ang bawat unit bago ipadala.

    Routine test sa 100% ng unit, type test ng CNAS-accredited na pambansang laboratoryo, at management system na sertipikado sa ISO 9001, ISO 14001 at ISO 45001.

    Routine test sa bawat transformer
    01Winding resistance at voltage ratio✓ 100%
    02Vector group at polarity✓ 100%
    03No-load loss at current✓ 100%
    04Load loss at impedance✓ 100%
    05Applied at induced voltage withstand✓ 100%
    06Partial discharge (dry type)✓ 100%
    07Oil dielectric strength at tightness (oil type)✓ 100%
    • IEC 60076-1/-2/-3/-5/-11
    • IEC 62271-200/-202
    • GB 1094
    • GB/T 10228
    • GB/T 6451
    • GB/T 17467
    • IEC 60502-2
    ISO 9001 · 14001 · 45001ISO 9001 · 14001 · 45001ISO 9001 · 14001 · 45001

    ISO 9001 · 14001 · 45001

    Type-test reportType-test reportType-test report

    Type-test report

    ConductorXLPE Cu screenArmourPVC / PE Power cable

    08 — Power cable

    Ang transformer ay kasinghusay lang ng cable na nagpapakain dito.

    Nagsimula ang Xinya bilang manufacturer ng power cable. Bawat transformer at substation ay puwedeng ipadala kasama ang MV at LV cable na tinukoy para dito — sukat, terminated at tested.

    • MV power cable

      XLPE-insulated copper cable 6/10 hanggang 26/35 kV ayon sa IEC 60502-2, armoured o hindi, mula sa sarili naming linya.

    • Termination at joint

      Heat-shrink o cold-shrink termination na tugma sa bushing, elbow connector at switchgear.

    • Iisang set ng test record

      Routine test ng cable na kasama ng test report ng transformer.

    • Iisang shipment

      Transformer, substation at cable drum sa iisang container booking.

    09 — Humingi ng quote

    Ano talaga ang matatanggap mo

    Bawat inquiry ay sinasagot ng engineer, hindi ng sales script.

    01Selection at drawing sa loob ng 24 oras

    Ipadala ang load at voltage. Ibabalik namin ang rating, impedance, guaranteed losses at outline drawing.

    Humingi ng quote
    02Witness test bago bayaran ang balanse

    Dumalo sa factory acceptance test o panoorin nang live, kasama ang report ng iyong serial number.

    Humingi ng quote
    03Dokumentong pumapasa sa utility

    Type-test report, routine-test certificate, drawing at manual na handa para sa utility, consultant at customs.

    Humingi ng quote
    04Cable na gawa para sa iyong layout

    MV at LV cable na pinutol at tinerminate ayon sa iyong drawing — kasama ng transformer.

    Humingi ng quote

    10

    Mula inquiry hanggang energization

    Malinaw na proseso, may engineer — hindi salesperson — sa bawat hakbang.

    1. STEP 01Inquiry

      Ipadala ang load, voltage, site at pamantayan. Sagot sa loob ng isang araw.

    2. STEP 02Engineering

      Rating, impedance, losses at outline drawing para aprubahan.

    3. STEP 03Produksyon

      Core, winding, casting o oil filling, may progress photo.

    4. STEP 04Testing

      Routine test, may opsyong witness test o video FAT.

    5. STEP 05Delivery

      Seaworthy packing, dokumento at gabay sa pag-install.

    11

    Mga tanong ng bumibili

    Maikling sagot mula sa aming mga engineer. Magtanong pa sa inquiry form.

    Oil-immersed o dry-type: alin ang pipiliin?

    Oil-immersed para sa outdoor at pinakamababang gastos bawat kVA; cast-resin dry type para sa indoor room, high-rise, ospital at saanman nililimitahan ng fire rules ang langis.

    Paano sukatin ang distribution transformer?

    Hatiin ang maximum demand sa kW sa power factor para makuha ang kVA, magdagdag ng margin para sa paglago, at piliin ang susunod na standard rating para tumakbo sa ilalim ng mga 90% load. Ginagawa ito ng aming tool sa ilang segundo.

    Anong pamantayan ang sinusunod ng inyong transformer?

    IEC 60076 (oil), IEC 60076-11 (dry type), IEC 62271-202 (prefabricated substation) at ang Chinese GB 1094 / GB/T 10228 / GB/T 6451. Puwedeng i-engineer ang ibang voltage, frequency at pamantayan.

    Ano ang pagkakaiba ng S11, S13 at amorphous?

    Mga antas ito ng efficiency. Ang S13 ay may 20–30% na mas mababang no-load loss kaysa S11, at ang amorphous core ay mga 70% na mas mababa — pinakamainam kapag magaan ang load.

    Gaano katagal ang lead time?

    Karaniwang naipapadala ang standard distribution transformer at substation sa loob ng ilang linggo matapos aprubahan ang drawing; mas matagal ang power transformer. May tiyak na petsa ang bawat quotation.

    Puwede ba akong mag-witness ng test bago ipadala?

    Oo — sa pabrika, sa live video, o sa pamamagitan ng third-party inspector. Kasama sa shipment ang test report ng iyong serial number.

    ● RFQ

    May pinaplanong transformer o substation project?

    Sabihin ang load, voltage level at site. Makakatanggap ka ng selection, drawing at quotation sa loob ng isang araw ng trabaho.