Tungkol sa Xinya Power

Isang manufacturer ng power cable na naghahatid ng kumpletong transformer at substation package.

01

Mula cable hanggang kumpletong substation

Nagsimula ang Xinya Power Cables sa paggawa ng power cable. Paulit-ulit na hinihingi ng mga customer ang transformer sa kabilang dulo ng cable — kaya nagdagdag kami ng transformer at substation, at ipinapadala na namin ang dalawa bilang isang package.

02

Qualified na paggawa

Core team na may 30 taong karanasan sa transformer, management system na sertipikado sa ISO 9001 / 14001 / 45001, at type test ng CNAS-accredited na pambansang laboratoryo.

03

Engineering support

Pinipili ng aming engineer ang rating, sinusuri ang losses at impedance, tinutukoy ang cable at inihahanda ang dokumento para sa iyong utility — sa 13 wika.

40 MVApinakamalaking rating · mula 10 kVA
220 kVpinakamataas na voltage class
−70%no-load loss gamit ang amorphous core
13wika ng engineering support

Ang aming pangako

  • Tapat na data sheet na may guaranteed losses
  • Katugmang cable sa bawat transformer
  • Mabilis at dokumentadong quotation
  • After-sales support sa iba’t ibang time zone

Paggawa

Gawa sa totoong production line.

Ginagawa ang aming transformer sa totoong production line: foil at wire winding, vacuum resin casting, oil-filling line at kumpletong routine-test bay.

Assembly line ng cast-resin transformer
01Assembly line ng cast-resin transformer
Coil winding at core stacking
02Coil winding at core stacking
Routine test control desk
03Routine test control desk
Final assembly ng oil-immersed
04Final assembly ng oil-immersed
Vacuum-cast resin coil
05Vacuum-cast resin coil
Lead at tap connection
06Lead at tap connection

Kalidad at sertipikasyon

Tinetest ang bawat unit bago ipadala.

Routine test sa 100% ng unit, type test ng CNAS-accredited na pambansang laboratoryo, at management system na sertipikado sa ISO 9001, ISO 14001 at ISO 45001.

Routine test sa bawat transformer
01Winding resistance at voltage ratio✓ 100%
02Vector group at polarity✓ 100%
03No-load loss at current✓ 100%
04Load loss at impedance✓ 100%
05Applied at induced voltage withstand✓ 100%
06Partial discharge (dry type)✓ 100%
07Oil dielectric strength at tightness (oil type)✓ 100%
  • IEC 60076-1/-2/-3/-5/-11
  • IEC 62271-200/-202
  • GB 1094
  • GB/T 10228
  • GB/T 6451
  • GB/T 17467
  • IEC 60502-2
ISO 9001 · 14001 · 45001ISO 9001 · 14001 · 45001ISO 9001 · 14001 · 45001

ISO 9001 · 14001 · 45001

Type-test reportType-test reportType-test report

Type-test report

Mula inquiry hanggang energization

Malinaw na proseso, may engineer — hindi salesperson — sa bawat hakbang.

  1. STEP 01Inquiry

    Ipadala ang load, voltage, site at pamantayan. Sagot sa loob ng isang araw.

  2. STEP 02Engineering

    Rating, impedance, losses at outline drawing para aprubahan.

  3. STEP 03Produksyon

    Core, winding, casting o oil filling, may progress photo.

  4. STEP 04Testing

    Routine test, may opsyong witness test o video FAT.

  5. STEP 05Delivery

    Seaworthy packing, dokumento at gabay sa pag-install.

● RFQ

May pinaplanong transformer o substation project?

Sabihin ang load, voltage level at site. Makakatanggap ka ng selection, drawing at quotation sa loob ng isang araw ng trabaho.