Dry-type transformer

SCB10 / SCB11 / SCB13 Cast-Resin Dry-Type Transformer

Fire-safe at walang langis para sa gusali, ospital at pabrika.

30–2,500 kVA
6–11 / 0.4 kV
IEC 60076-11

Epoxy cast-resin dry-type transformer mula 30 hanggang 2,500 kVA para sa 6–11 kV. Walang langis, self-extinguishing at walang maintenance — standard para sa indoor substation, high-rise, paliparan at metro. Opsyonal ang IP20/IP23 enclosure at fan para sa +20% output.

Mga modeloSCB10SCB11SCB13

  • IEC 60076-11
  • GB/T 10228
  • GB/T 1094.11
  • ISO 9001

Mga tampok

  • 30 – 2,500 kVA, 6–11 kV / 0.4 kV
  • SCB13 no-load loss ≈25–30% mas mababa sa SCB10
  • Pt100 temperature controller, AF fan (+20%)
  • IP00 / IP20 / IP23 enclosure sa steel, aluminium o stainless

Pangunahing parameter

ModeloSCB10SCB11SCB13
Rated na kapasidad30 – 2,500 kVA
HV na boltahe6, 6.3, 6.6, 10, 10.5, 11 kV
LV na boltahe0.4 kV
Tapping range±5% or ±2×2.5%
Vector groupDyn11, Yyn0
Short-circuit impedance4.0% (≤630 kVA) · 6.0% (630–2,500 kVA)
WindingsCopper foil LV / copper wire HV, epoxy cast
Insulation classF (155 °C) · H (180 °C) on request
Cooling methodAN / AF (AF: +20% output may fan)
Protection & monitoringPt100 sensors, temperature controller with RS232/485, fan control, alarm & trip
Ingress protectionIP00 · IP20 / IP23 enclosure
InstalasyonIndoor
Mga pamantayanIEC 60076-11, GB/T 1094.11, GB/T 10228

Ratings at losses

Rated na kapasidadkVAShort-circuit impedance%No-load lossSCB10WLoad lossSCB10WNo-load lossSCB11WLoad lossSCB11WNo-load lossSCB13WLoad lossSCB13WNo-load currentSCB13%
304.01907101707101356401.7
504.02701,0002401,0001959001.7
804.03701,3803301,3802651,2401.3
1004.04001,5703601,5702901,4101.3
1254.04701,8504201,8503401,6601.1
1604.05402,1304802,1303851,9101.1
2004.06202,5305502,5304452,2701
2504.07202,7606402,7605152,4801
3154.08803,4707903,4706353,1200.8
4004.09803,9908803,9907053,5900.8
5004.01,1604,8801,0404,8808354,3900.8
6304.01,3405,8801,2005,8809655,2900.7
6306.01,3005,9601,1705,9609355,3600.7
8006.01,5206,9601,3606,9601,0906,2600.7
1,0006.01,7708,1301,5908,1301,2707,3100.7
1,2506.02,0909,6901,8809,6901,5008,7200.7
1,6006.02,45011,7002,20011,7301,76010,5000.7
2,0006.03,05014,4002,74014,4402,19013,0000.6
2,5006.03,60017,1003,24017,1002,59015,4000.6

Ayon sa GB/T 10228; pinal na datos ayon sa test report.

Magtanong tungkol sa produktong ito

SCB10 / SCB11 / SCB13 Cast-Resin Dry-Type Transformer

Karaniwang sumasagot sa loob ng isang araw ng trabaho.

o [email protected]Mag-chat sa WhatsApp