
Oil-immersed transformer
33 kV Oil-Immersed Distribution Transformer
Gawa para sa 11 kV at 33 kV na network sa Africa, Middle East at Asia.
- 25–2,500 kVA
- 11 / 33 kV
- IEC 60076
Three-phase oil-immersed distribution transformer mula 25 hanggang 2,500 kVA na may 11, 20, 33 o 35 kV primary at 415 V secondary. Conservator na may Buchholz protection, ONAN cooling (ONAF mula 1,500 kVA) at tropical-grade na pintura.
Mga modeloXY-S13-33
- IEC 60076
- GB 1094
- ISO 9001
Mga tampok
- 25 – 2,500 kVA, 11 / 33 kV → 0.415 kV
- Conservator, Buchholz relay, pressure relief
- ONAN, ONAF mula 1,500 kVA
- IEC 60076, utility specification kapag hiniling
Pangunahing parameter
| Rated na kapasidad | 25 – 2,500 kVA |
|---|---|
| HV na boltahe | 11 kV, 20 kV, 33 kV, 35 kV |
| LV na boltahe | 0.415 kV / 0.4 kV |
| Tapping range | ±5% or ±2×2.5% |
| Vector group | Dyn11, YNd11, Yd11 |
| Cooling method | ONAN · ONAF from 1,500 kVA |
| Tank / enclosure | Conservator with radiators |
| Insulation level | LI125 AC55 (20 kV) · LI200 AC85 (35 kV) |
| Protection & monitoring | Buchholz relay, oil-level gauge, pressure relief valve, dial thermometer |
| Instalasyon | Nakakabit sa poste / pad-mounted / Outdoor |
| Mga pamantayan | IEC 60076, GB 1094.1/2/3/5, GB/T 6451 |
Standard ratings
| Rated na kapasidadkVA | HV na boltahekV | LV na boltahekV | Cooling method |
|---|---|---|---|
| 25 | 11 / 33 | 0.415 | ONAN |
| 50 | 11 / 33 | 0.415 | ONAN |
| 100 | 11 / 33 | 0.415 | ONAN |
| 200 | 11 / 33 | 0.415 | ONAN |
| 315 | 11 / 33 | 0.415 | ONAN |
| 500 | 11 / 33 | 0.415 | ONAN |
| 1,000 | 33 | 0.415 | ONAN |
| 1,500 | 33 | 0.415 | ONAN / ONAF |
| 2,500 | 33 | 0.415 | ONAF |
Indicative na halaga — puwedeng i-engineer ang ibang boltahe, rating at cooling.
Kaugnay na produkto
S11-M
Oil-immersed transformerS13 Oil-Immersed Distribution Transformer 10 kVSealed, low-loss, walang maintenance — ang workhorse ng bawat distribution network.
- Rated na kapasidad
- 30–2,500 kVA
- Rated na boltahe
- 6–11 / 0.4 kV
- Mga pamantayan
- IEC 60076
SBH15-M
Oil-immersed transformerSBH15 Amorphous-Alloy Oil-Immersed TransformerMga 70% mas mababang no-load loss — tipid sa bawat oras na naka-energize.
- Rated na kapasidad
- 30–2,500 kVA
- Rated na boltahe
- 6–11 / 0.4 kV
- Mga pamantayan
- −70% P0
SCB10
Dry-type transformerSCB10 / SCB11 / SCB13 Cast-Resin Dry-Type TransformerFire-safe at walang langis para sa gusali, ospital at pabrika.
- Rated na kapasidad
- 30–2,500 kVA
- Rated na boltahe
- 6–11 / 0.4 kV
- Mga pamantayan
- IEC 60076-11
Magtanong tungkol sa produktong ito
33 kV Oil-Immersed Distribution Transformer
Karaniwang sumasagot sa loob ng isang araw ng trabaho.


