
Power transformer
110 / 132 / 220 kV Power Transformer
High-voltage grid transformer hanggang 40 MVA, dinisenyo bawat proyekto.
- 16–40 MVA
- 110–220 kV
- IEC 60076
Power transformer para sa transmission substation at malalaking industrial o renewable connection: 16–40 MVA sa 110, 132 o 220 kV, OLTC, ONAF/OFAF cooling at opsyonal na online gas monitoring.
Mga modeloXY-SZ11-110XY-SFZ11-220
- IEC 60076
- GB 1094
Mga tampok
- 16 – 40 MVA, 110 / 132 / 220 kV
- OLTC, YNd11 / YNyn0d11
- ONAF / OFAF cooling
- Puwedeng i-witness ang factory test
Pangunahing parameter
| Modelo | XY-SZ11-110 | XY-SFZ11-220 |
|---|---|---|
| Rated na kapasidad | 16,000 – 40,000 kVA (larger on request) | |
| HV na boltahe | 110, 132, 220 kV | |
| LV na boltahe | 11, 33, 66 kV | |
| Tap changer | On-load (OLTC) | |
| Vector group | YNd11, YNyn0d11 | |
| Short-circuit impedance | 8.0 – 12.5% | |
| Cooling method | ONAF / OFAF | |
| Tank / enclosure | Conservator with radiators | |
| Protection & monitoring | Buchholz relay, WTI / OTI, pressure relief, bushing CTs, online DGA (option) | |
| Instalasyon | Outdoor | |
| Mga pamantayan | IEC 60076, GB 1094, GB/T 6451 | |
Standard ratings
| Rated na kapasidadMVA | HV na boltahekV | LV na boltahekV | Cooling method | Tap changer | Short-circuit impedance% |
|---|---|---|---|---|---|
| 16 | 110 / 132 | 11 / 33 | ONAF | OLTC | 8.0 |
| 20 | 110 / 132 | 11 / 33 | ONAF | OLTC | 8.0 |
| 25 | 132 / 220 | 33 / 66 | ONAF / OFAF | OLTC | 10.0 |
| 31.5 | 132 / 220 | 33 / 66 | OFAF | OLTC | 10.0 |
| 40 | 132 / 220 | 33 / 66 | OFAF | OLTC | 12.5 |
Indicative na halaga — puwedeng i-engineer ang ibang boltahe, rating at cooling.
Kaugnay na produkto
XY-SZ11-35
Power transformer35 kV / 66 kV Power Transformer na may OLTCSubstation at industrial power transformer mula 3.15 hanggang 20 MVA.
- Rated na kapasidad
- 3.15–20 MVA
- Rated na boltahe
- 33–66 kV
- Mga pamantayan
- IEC 60076
S11-M
Oil-immersed transformerS13 Oil-Immersed Distribution Transformer 10 kVSealed, low-loss, walang maintenance — ang workhorse ng bawat distribution network.
- Rated na kapasidad
- 30–2,500 kVA
- Rated na boltahe
- 6–11 / 0.4 kV
- Mga pamantayan
- IEC 60076
SBH15-M
Oil-immersed transformerSBH15 Amorphous-Alloy Oil-Immersed TransformerMga 70% mas mababang no-load loss — tipid sa bawat oras na naka-energize.
- Rated na kapasidad
- 30–2,500 kVA
- Rated na boltahe
- 6–11 / 0.4 kV
- Mga pamantayan
- −70% P0
Magtanong tungkol sa produktong ito
110 / 132 / 220 kV Power Transformer
Karaniwang sumasagot sa loob ng isang araw ng trabaho.


