HV switchgear, transformer at LV board sa iisang weatherproof na enclosure.
- 100–1,600 kVA
- 12 / 0.4 kV
- IEC 62271-202
Pinagsasama ng YB prefabricated substation (IEC 62271-202 / GB/T 17467) ang 12 kV switch room, 100–1,600 kVA transformer at LV room na may 8–15 outgoing feeder. Naiinstall sa loob ng ilang araw sa subdivision, pabrika, minahan at ospital.
Mga modeloYB-12/0.4
- IEC 62271-202
- GB/T 17467
- ISO 9001
Mga tampok
- 12 kV / 0.4 kV, 100 – 1,600 kVA
- In-line (目) o matrix (品) na layout
- Natural + fan ventilation, thermal-barrier na bubong
- Monitoring, alarm at interlock
Pangunahing parameter
| Rated na kapasidad | 100 – 1,600 kVA |
|---|---|
| HV na boltahe | 10 (10.5) kV · max. 12 kV |
| LV na boltahe | 0.4 kV |
| Istruktura | HV room + transformer room + LV room · 目-shape (in-line) or 品-shape layout |
| Ingress protection | IP34D |
| Sound level | ≤ 55 dB(A) |
| Outgoing circuits | HV 1–4 · LV 8–15 |
| Service conditions | −30 ~ +40 °C · Altitude ≤ 2,000 m · humidity ≤ 90% · wind ≤ 35 m/s |
| Instalasyon | Outdoor |
| Mga pamantayan | IEC 62271-202, GB/T 17467-2010 |
Electrical data
| Item | HV compartment | Transformer | LV compartment |
|---|---|---|---|
| Rated na boltahe (kV) | 12 | 10 (10.5) / 0.4 | 0.4 |
| Rated current (A) | 630 | — | 100 – 2,500 |
| Frequency (Hz) | 50 | 50 | 50 |
| Rated na kapasidad (kVA) | — | 100 – 1,600 | — |
| Short-time withstand current (kA) | 20 | — | 30 |
| Peak withstand current (kA) | 50 | — | 63 |
| Short-circuit making current (kA) | 50 | — | 63 |
| Power-frequency withstand (kV) | 42 / 48 | 35 / 28 (5 min) | 20 / 2.5 |
| Lightning impulse withstand (kV) | 75 / 85 | 75 | — |
| Outgoing circuits | 1 – 4 | 1 | 8 – 15 |
Kaugnay na produkto
S11-M
Oil-immersed transformerS13 Oil-Immersed Distribution Transformer 10 kVSealed, low-loss, walang maintenance — ang workhorse ng bawat distribution network.
- Rated na kapasidad
- 30–2,500 kVA
- Rated na boltahe
- 6–11 / 0.4 kV
- Mga pamantayan
- IEC 60076
SBH15-M
Oil-immersed transformerSBH15 Amorphous-Alloy Oil-Immersed TransformerMga 70% mas mababang no-load loss — tipid sa bawat oras na naka-energize.
- Rated na kapasidad
- 30–2,500 kVA
- Rated na boltahe
- 6–11 / 0.4 kV
- Mga pamantayan
- −70% P0
XY-S13-33
Oil-immersed transformer33 kV Oil-Immersed Distribution TransformerGawa para sa 11 kV at 33 kV na network sa Africa, Middle East at Asia.
- Rated na kapasidad
- 25–2,500 kVA
- Rated na boltahe
- 11 / 33 kV
- Mga pamantayan
- IEC 60076